- Power saving and low operation cost: No complicated water treatment equipment is required, saving water resources, and being able to replace water-medium boiler for heating in water shortage regions.
- Precise temperature control: Stable heat supply, precise temperature regulation, and high automation.
- High thermal efficiency: Closed cycle is adopted for heat supply, without waste heat emission, but with good load adaptability, being able to maintain the beast thermal efficiency on different operating conditions, and achieving high comprehensive thermal efficiency.
- Safe and reliable: Equipped with perfect running control and safety monitoring devices. Heating system runs opening, with high safety factor.
- High temperature and low pressure: It can obtain higher operating temperature under lower working pressure.
- The choice of international famous brand burner and advanced automatic control system makes the boiler more stable in combustion, more convenient to operate, more safe and reliable in running.
- Bore adopts double dense coil tubes, and enough heating surface is arranged to reduce the heat load on the surface of the tube so that the use of heat conduction oil is safer.
- Medium flow is reasonable; heat conduction oil is from low (inlet) to high (outlet); the gas produced by running is difficult to stay in the boiler and can be conveniently discharged from the system.
- Hearth size matches with combustion flame perfectly, and positive pressure combustion is adopted so that radiant thermal efficiency is high.
- The design and manufacture of organic heat carrier furnace are carried out in accordance with the requirements of TSG G001-2012 Technical Regulation for Safety of Boiler, TSG G0002-2010 Supervision Regulation on Saving Energy Technology for Boiler and GB/T17410 Organic Heat Carrier Furnace.
Item |
UNIT |
Model |
||||||||
YY(Q)W-98Y、Q |
YY(Q)W-240Y、Q |
YY(Q)W-350Y、Q |
YY(Q)W-500Y、Q |
YY(Q)W-700Y、Q |
YY(Q)W-1000Y、Q |
YY(Q)W-1200Y、Q |
YY(Q)W-1400Y、Q |
|||
Rated thermal power |
Kcal |
10*10⁴ |
20*10⁴ |
30*10⁴ |
40*10⁴ |
60*10⁴ |
80*10⁴ |
100*10⁴ |
120*10⁴ |
|
KW |
120 |
230 |
350 |
470 |
700 |
930 |
1200 |
1400 |
||
Thermal efficiency |
% |
75 |
80 |
85 |
85 |
85 |
85 |
90 |
90 |
|
Designed pressure |
Mpa |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
Designed temperature |
℃ |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
|
Oil capacity inside furnace |
m³ |
0.08 |
0.12 |
0.25 |
0.31 |
0.36 |
0.49 |
0.61 |
1.05 |
|
Motor power |
KW |
5.5 |
7.5 |
7.5 |
11 |
22 |
22 |
22 |
22 |
|
Circulating pump flow |
m³/h |
12.5 |
25 |
25 |
45 |
100 |
100 |
100 |
100 |
|
Circulating pump lift |
m |
50 |
54 |
54 |
42 |
55 |
55 |
55 |
55 |
|
Pipe connection caliber |
mm |
50 |
65 |
80 |
80 |
100 |
100 |
125 |
125 |
|
Installed capacity of system |
kw |
5.63 |
7.75 |
8 |
11.5 |
23.1 |
23.5 |
23.5 |
24.2 |
|
Gas/oil consumption |
Gas m³/h (oil kg/h) |
11.5(9.7) |
23(19.5) |
35(29.7) |
46.5(39.4) |
70(59.3) |
93(78.8) |
116(98.3) |
140(117.3) |
|
Reference size of complete machine |
Length (L) mm |
2600 |
2900 |
2900 |
3400 |
3750 |
4200 |
4400 |
5400 |
|
Width (W) mm |
1600 |
1700 |
1700 |
2000 |
2200 |
2200 |
2350 |
2250 |
||
Height (H) mm |
1600 |
1900 |
2200 |
2200 |
2550 |
2550 |
2300 |
2900 |
||
The above specifications are subject to change without prior notice. Special specifications can be modified separately. |