- Tel: +86-18020208608
- E-mail: aodewm@aodejx.com
- Isolated explosion-proof electric cabinet
- Explosion-proof electrical accessories outside electrical box
- Explosion-proof equipment (optional)
- Air blowing and oil returning function (optional)
- Thermometer for return oil
- Automatic air exhausting after startup
- Switchover of heating power
- RS485 communication function for automated management (optional)
- Delayed shutdown for cooling (optional)
- BY-PASS pressure release loop for hot oil
- Customizable multi-point temperature control unit
- Customizable oil pump horsepower and heating power
- Electric appliances: SIEMENS, Weidmuller, LS, JUMO, ABB, WEST
- Temperature control range: Natural temperature +45°C~300°C
- CE compliant
- Special pipeline for organic heat carrier furnace
- Control mode: Control by using imported microcomputer or PLC (optional)
- Improved safety protection, fault indication, maintenance and service without professionals
Item |
Unit |
Model |
|
||||||||
AEOT-10BF-18 |
AEOT-20BF-24 |
AEOT-30BF-36 |
AEOT-40BF-45 |
AEOT-50BF-60 |
AEOT-75BF-75 |
AEOT-75BF-90 |
AEOT-100BF-100 |
AEOT-150BF-150 |
|||
Temperature control range |
℃ |
Water inlet temperature +45℃-300℃ |
|
||||||||
Temperature control precision |
℃ |
PID±1℃ |
|
||||||||
Power supply |
|
AC3∮380V 50Hz(3phase+Earth);AC3∮440V 60Hz;AC3∮460V 60Hz |
|
||||||||
|
|
Heat conduction oil |
|||||||||
Heat transfer medium |
|
Indirect cooling |
No cooling |
||||||||
Cooling method |
L |
67 |
67 |
67 |
80 |
80 |
100(External) |
150(External) |
150(External) |
200(External) |
|
Expansion tank capacity |
KW |
15/28 |
18/24 |
30/36 |
36/40/45/50 |
40/45/50 |
50/60/75 |
80(40+40)/90(45+45) |
100(50+50) |
100(50*3) |
|
Heating capacity |
KW |
1.5 |
1.5 |
2.2 |
3 |
4 |
5.5 |
5.5 |
7.5 |
11 |
|
Pump power |
m³/h |
6.5 |
6.5 |
10 |
12.5 |
16 |
12.5(18) |
12.5(18) |
5.0(4.8) |
4.2 |
|
Pump flow |
kg/cm² |
2.8 |
2.8 |
2.8 |
3 |
3.2 |
5.0(4.0) |
5.0(4.0) |
5.0(4.8) |
4.2 |
|
Pump pressure |
KW |
16.5 |
25.5 |
38.5 |
48 |
64 |
81 |
96 |
108 |
161 |
|
Maximum power consumption |
|
Phase loss / lack of oil / over temperature / overload / oil spill / heating abnormal alarm / trip power off |
|||||||||
Alarm function |
inch |
1/2 |
1/2 |
1/2 |
1/2 |
1/2 |
1/2 |
NA |
NA |
NA |
|
Cooling water pipe |
inch |
1 |
1 |
1 |
1-1/4 |
1-1/4 |
1-1/2 |
1-1/2 |
2 |
2 |
|
Circulation oil pipe |
mm |
2000*500*1250 |
2100*600*1350 |
2250*700*1550 |
2250*800*1650 |
2450*800*1650 |
2450*800*1650 |
2250*800*1800 |
2300*800*1800 |
2450*800*1800 |
|
Reference size of complete machine |
L*Φ |
1500*Φ285 |
1600*Φ340 |
1750*Φ340 |
1650*Φ520 |
1950*Φ520 |
2000*Φ520 |
1650*Φ520 |
1800*Φ520 |
2000*Φ520 |
|
The above specifications are subject to change without prior notice. Special specifications can be modified separately. |