- Tel: +86-18020208608
- E-mail: aodewm@aodejx.com
- Compressor head imported from Europe or America
- Steel tube welded without oxygen
- RS485 communication function for automated management (optional)
- Imported advanced components with long service life
- Electric appliances: SIEMENS, Weidmuller, LG, MOELLER, ABB, WEST
- Control mode: Control by using imported microcomputer or PLC (optional)
- Improved safety protection, fault indication, maintenance and service without professionals
- High efficiency evaporator and condenser, being able to save more than 30% energy
- C-20 above adopt two sets of compressor heads, used alone or in combination
Item |
Unit |
Model |
||||||||||||||||||
AC-0.5AS |
AC-01AS |
AC-02AS |
AC-03AS |
AC-04AS |
AC-05AS |
AC-06AS |
AC-08AD |
AC-10AD |
AC-12AS |
AC-15AD |
AC-20AD |
AC-25AD |
AC-30AT |
AC-36AT |
AC-40AF |
AC-50AF |
AC-60AF |
|||
Refrigerating capacity |
kcal/h |
1290 |
2494 |
4816 |
7482 |
9632 |
11782 |
14620 |
19264 |
23564 |
28724 |
36550 |
49536 |
57448 |
70692 |
86172 |
94256 |
114896 |
154800 |
|
kW |
1.5 |
2.9 |
5.6 |
8.7 |
11.2 |
13.7 |
17 |
22.4 |
27.4 |
33.4 |
42.5 |
57.6 |
66.8 |
82.2 |
100.2 |
109.6 |
133.6 |
180 |
||
Total power input |
kW |
1.15 |
1.58 |
2.4 |
3.53 |
4.13 |
5.15 |
6.05 |
8.19 |
10.2 |
11.8 |
15.6 |
20 |
23.2 |
30.3 |
36.1 |
40.4 |
46.8 |
64.3 |
|
Maximum running current |
A |
6.9 |
10.53333333 |
16.94117647 |
9.151851852 |
12.51515152 |
14.1625 |
16.05102041 |
24.81818182 |
28.05 |
28.27083333 |
41.184 |
50 |
55.58333333 |
83.325 |
86.48958333 |
111.1 |
112.125 |
165.4779412 |
|
Recommended supply cable diameter |
mm2 |
3×1.5 |
3×1.5 |
3×2.5 |
3×4+2×4 |
3×4+2×4 |
3×4+2×4 |
3×4+2×4 |
3×6+2×4 |
3×6+2×4 |
3×6+2×4 |
3×10+2×4 |
3×10+2×4 |
3×25+2×10 |
3×25+2×10 |
3×35+2×16 |
3×70+2×35 |
3×70+2×35 |
3×95+2×50 |
|
Refrigerant |
|
R22 |
||||||||||||||||||
Running control method |
|
Digital display microcomputer temperature control unit |
||||||||||||||||||
Power supply |
|
1N,220V,50Hz |
3N,380V,50Hz |
|||||||||||||||||
Safety protection devices |
|
Overload protection, reverse/default phase protection (three-phase), high/low pressure protection, low water flow protection, low level protection, freeze protection, etc |
||||||||||||||||||
Compressor |
Type |
|
Hermetic rotor or gyral |
|||||||||||||||||
Compressor power |
kW |
0.5×1 |
0.9×1 |
1.7×1 |
2.7×1 |
3.3×1 |
4×1 |
4.9×1 |
3.3×2 |
4×2 |
9.6×1 |
8+4 |
8×2 |
9.6×2 |
8×3 |
9.6×3 |
8×4 |
9.6×4 |
13.6×4 |
|
Condenser |
Type |
|
Copper sleeve fin |
|||||||||||||||||
Air flow |
m3/h |
500 |
1000 |
2000 |
3000 |
4000 |
5000 |
6000 |
8000 |
10000 |
12000 |
15000 |
20000 |
25000 |
30000 |
36000 |
40000 |
50000 |
60000 |
|
Fan power |
kW |
0.1×1 |
0.13×1 |
0.15×1 |
0.14×2 |
0.14×2 |
0.2×2 |
0.2×2 |
0.42×2 |
0.55×2 |
0.55×2 |
0.8×2 |
1.1×2 |
1.1×2 |
1.1×3 |
1.1×3 |
1.1×4 |
1.1×4 |
1.1×4 |
|
Evaporator |
Type |
|
Water tank coil |
Dry shell-tube |
||||||||||||||||
Inlet/outlet pipe diameter |
Inch |
1月2日 |
1月2日 |
1月2日 |
1 |
1 |
1 |
1 |
1.5 |
2 |
2 |
2 |
2.5 |
2.5 |
2.5 |
2.5 |
3 |
3 |
3 |
|
Water tank capacity |
L |
30 |
30 |
30 |
70 |
70 |
70 |
70 |
120 |
120 |
120 |
120 |
200 |
200 |
200 |
200 |
400 |
400 |
400 |
|
Pump |
Flow |
m3/h |
0.3 |
0.5 |
1 |
1.5 |
1.9 |
2.4 |
2.9 |
3.9 |
4.7 |
5.7 |
7.3 |
9.9 |
11.5 |
14.1 |
17.2 |
18.9 |
23 |
31 |
Pressure |
bar |
1.8 |
1.8 |
1.8 |
1.8 |
1.7 |
2.2 |
1.7 |
1.7 |
1.9 |
1.9 |
1.9 |
2.1 |
2.1 |
2.1 |
2 |
2.1 |
2.1 |
2 |
|
Power |
kW |
0.375 |
0.375 |
0.375 |
0.375 |
0.375 |
0.75 |
0.75 |
0.75 |
1.5 |
1.5 |
1.5 |
2.2 |
2.2 |
2.2 |
2.2 |
4 |
4 |
4 |
|
A (length) |
mm |
680 |
680 |
820 |
1150 |
1150 |
1230 |
1230 |
1480 |
1480 |
1600 |
1900 |
2200 |
2320 |
2600 |
2600 |
2400 |
2800 |
3200 |
|
B (width) |
mm |
420 |
420 |
520 |
560 |
560 |
660 |
660 |
720 |
720 |
800 |
900 |
950 |
1100 |
1100 |
1100 |
1700 |
1700 |
2000 |
|
C (height) |
mm |
790 |
790 |
1170 |
1380 |
1380 |
1400 |
1400 |
1630 |
1630 |
1800 |
1850 |
2050 |
2050 |
2050 |
2050 |
2050 |
2100 |
2100 |
|
Refrigerant filling capacity |
kg |
0.6 |
0.8 |
1.8 |
2.7 |
3.5 |
4.3 |
5 |
7 |
8.6 |
10 |
13 |
17 |
21 |
25 |
30 |
33 |
42 |
50 |
|
Notes |
||||||||||||||||||||
1. The above parameters are based on that chilled water inlet/outlet temperature is 15°C/10°C and ambient temperature is 35°C. |
||||||||||||||||||||
2. The company reserves the right to change the above parameters without prior notice. |